CNC lathe · G-code
G90: O.D./I.D. turning cycle
On a lathe, G90 turns one straight or tapered pass from X and Z; each X on the lines after it is another pass. Haas lists it in modal group 01. Formats below from Haas and Fanuc, each from its maker. LinuxCNC has no such code.
On a mill, G90 is absolute positioning.
Worked example
Three passes down to 1.75" diameter. Written for this page in the Haas format.
G00 X2.1 Z0.1G90 X1.9 Z-1. F0.01 (first pass)X1.8 (second pass)X1.75 (finish size)G00 X3.How each control writes it
Haas G90 X- Z- I- F-
One source: Haas Automation, the control's maker
- X
- X target (diameter)
- Z
- Z target
- U
- Incremental X to the target (diameter) (optional)
- W
- Incremental Z to the target (optional)
- I
- Taper: X distance and direction, radius, added to X at the target (optional)
- F
- Feedrate
- More passes: give each extra pass’s X on its own line.
- U, W, X and Z reach all four ZX quadrants; the taper can be plus or minus.
Source: Haas Automation, lathe G90
Fanuc G90 X(U)_ Z(W)_ F_ ; taper: G90 X(U)_ Z(W)_ R_ F_ ;
One source: FANUC, the control's maker
- X, Z
- End point of the cut
- U, W
- Or the distance to it, incremental (optional)
- R
- Taper amount, radius, signed (taper form) (optional)
- F
- Feedrate
- FANUC 0i-TF (lathe), G code system A (U and W are incremental), from its operator’s manual. On another FANUC model or G code system, check that control’s manual.
- The taper is R here, where Haas gives it with I.
Source: FANUC B-64604EN-1/01, Operator's Manual, 0i-TF (lathe), §4.1.1
Controls without it
- LinuxCNC: LinuxCNC has no single-pass turning cycle: its G90 is absolute distance mode. Rough with G71 or program G1 passes. Source (archived Oct 29, 2026)
How the controls differ
- Only Haas takes I.
- Only Fanuc takes R.
- A word two controls share can still mean different things: read each control's list above.
Haas follows Fanuc's numbering, but options and parameters differ between controls: check your control's manual.