Micrometer accuracy

A 0–1" digital micrometer is accurate to ±.0001", the median of three makers’ standard models: Mitutoyo prints ±.00005", Starrett ±.0001" and Fowler ±.00016". That’s the tool alone, new and checked at 20 °C; your hand, the temperature and dirt on the faces add to it.

Each maker’s accuracy, ± from the true size: Mitutoyo ±.00005", Starrett ±.0001", Fowler ±.00016"; the median is ±.0001".median ±.0001"MitutoyoStarrettFowler±.00005"±.0001"±.00016"−.00020.0002
0–1" digital micrometer: each maker’s accuracy for its standard model.

0–1" digital micrometer

0–1" digital micrometer: each maker’s published accuracy
MakerModel± inch± mm (as printed)
Mitutoyo293-340-30.00005"—
Starrett796.1XRL-1.0001"±0.002
Fowler54-860-001-1.00016"±0.004

Median: ±.0001" (makers span .00005–.00016")

Median of 3 makers

At the bench

Show

Check the tool on a gauge block or setting standard near the size you’re measuring before you trust it. Use the ratchet or friction thimble, wipe the faces, and hold the frame by its insulated part: a few degrees of hand heat in the frame shows up at this scale.