ISO 286 · Hole

F9 hole tolerance

F9 tolerance on a 25 mm hole is +0.072 / +0.020 mm, so the hole measures 25.020–25.072 mm. An F hole sits wholly above the nominal size, so it clears an h shaft. Grade 9 (IT9) sets the band’s width; the chart below gives it for every size to 500 mm.

f9 shaft on 25 mm: −0.020 / −0.072 mm. f9 shaft tolerance

F9 hole tolerance zone for every size range from 0–3 mm to 400–500 mm, against the zero line; 18–30 mm is +72 / +20 µm.tolerance zone F9, 18–30 mm: +72 / +20 µmsize range 0–3 to 400–500 mm
One band per size range against the zero line. The marked band holds 25 mm. Deviations to scale; the size ranges are evenly spaced, not to scale.

Limits by size

Deviations from the nominal size, over the first size up to and including the second. Inches are µm ÷ 25,400; ANSI B4.2 inch tables round differently, by a tenth or so.

F9 limits by nominal size
Size, mmUpper µmLower µmUpper inLower in
0–3+31+6+0.00122+0.00024
3–6+40+10+0.00157+0.00039
6–10+49+13+0.00193+0.00051
10–18+59+16+0.00232+0.00063
18–30+72+20+0.00283+0.00079
30–50+87+25+0.00343+0.00098
50–80+104+30+0.00409+0.00118
80–120+123+36+0.00484+0.00142
120–180+143+43+0.00563+0.00169
180–250+165+50+0.00650+0.00197
250–315+186+56+0.00732+0.00220
315–400+202+62+0.00795+0.00244
400–500+223+68+0.00878+0.00268

Checked against 3 published copies