ISO 286 · Hole · 180–250 mm
H11 hole tolerance, 180–250 mm
H11 tolerance for holes over 180 up to 250 mm is +0.290 / 0 mm (+0.01142 / 0 in). A 200 mm H11 hole measures 200.000–200.290 mm; a 250 mm one, 250.000–250.290 mm. The table gives each common size in the range in mm and inches.
H11 limits, over 180 up to 250 mm
Deviations from the nominal size. Inches are the µm values ÷ 25,400.
| Size, mm | Upper µm | Lower µm | Upper mm | Lower mm | Upper in | Lower in | Band µm |
|---|---|---|---|---|---|---|---|
| 180–250 | +290 | 0 | +0.290 | 0 | +0.01142 | 0 | 290 |
Checked against 3 published copies
Common sizes, H11 hole
The smallest and largest hole each size allows. 180 mm itself belongs to the range below.
| Size | Min mm | Max mm | Size in | Min in | Max in |
|---|---|---|---|---|---|
| 200 H11 | 200.000 | 200.290 | 7.8740 | 7.87402 | 7.88543 |
| 220 H11 | 220.000 | 220.290 | 8.6614 | 8.66142 | 8.67283 |
| 250 H11 | 250.000 | 250.290 | 9.8425 | 9.84252 | 9.85394 |
Checked against 3 published copies
ISO fits are metric; the inch columns convert them. ANSI B4.2 inch tables round differently, by a tenth or so.
Sources
Sources3
ISO 286-1 and 286-2. Every limit on this page comes from the same engine as the H11 chart, checked against these published copies of the tables: