ISO 286 · Hole

H9 hole tolerance

H9 tolerance on a 25 mm hole is +0.052 / 0 mm, so the hole measures 25.000–25.052 mm. An H hole’s smallest size is exactly the nominal size; the band runs up from it. Grade 9 (IT9) sets the band’s width; the chart below gives it for every size to 500 mm.

h9 shaft on 25 mm: 0 / −0.052 mm. h9 shaft tolerance

H9 hole tolerance zone for every size range from 0–3 mm to 400–500 mm, against the zero line; 18–30 mm is +52 / 0 µm.tolerance zone H9, 18–30 mm: +52 / 0 µmsize range 0–3 to 400–500 mm
One band per size range against the zero line. The marked band holds 25 mm. Deviations to scale; the size ranges are evenly spaced, not to scale.

Limits by size

Deviations from the nominal size, over the first size up to and including the second. Inches are µm ÷ 25,400; ANSI B4.2 inch tables round differently, by a tenth or so.

H9 limits by nominal size
Size, mmUpper µmLower µmUpper inLower in
0–3+250+0.000980
3–6+300+0.001180
6–10+360+0.001420
10–18+430+0.001690
18–30+520+0.002050
30–50+620+0.002440
50–80+740+0.002910
80–120+870+0.003430
120–180+1000+0.003940
180–250+1150+0.004530
250–315+1300+0.005120
315–400+1400+0.005510
400–500+1550+0.006100

Checked against 4 published copies

Fits that use H9

Fits that use H9
  • H9/d9 · Free running: Not for accuracy: big speed or temperature swings, heavy journal pressure
Any size and fit in the calculator

Sources

Sources4