ISO 286 · Hole · 80–120 mm

K7 hole tolerance, 80–120 mm

K7 tolerance for holes over 80 up to 120 mm is +0.010 / −0.025 mm (+0.00039 / −0.00098 in). A 100 mm K7 hole measures 99.975–100.010 mm; a 120 mm one, 119.975–120.010 mm. The table gives each common size in the range in mm and inches.

K7 hole tolerance zone, 80–120 mm: ES +10 µm, EI −25 µm against the zero line.ES +10 µmEI −25 µmtolerance zone K7zero line 80–120 mm
The tolerance zone against the zero line (the basic size). ES and EI are the hole’s upper and lower deviations. Deviations to scale; the part itself is not drawn.

K7 limits, over 80 up to 120 mm

Deviations from the nominal size. Inches are the µm values ÷ 25,400.

K7 deviations over 80 up to 120 mm
Size, mmUpper µmLower µmUpper mmLower mmUpper inLower inBand µm
80–120+10−25+0.010−0.025+0.00039−0.0009835

Checked against 4 published copies

Common sizes, K7 hole

The smallest and largest hole each size allows. 80 mm itself belongs to the range below.

K7 smallest and largest size for common sizes over 80 up to 120 mm
SizeMin mmMax mmSize inMin inMax in
90 K789.97590.0103.54333.542323.54370
100 K799.975100.0103.93703.936023.93740
110 K7109.975110.0104.33074.329724.33110
120 K7119.975120.0104.72444.723434.72480

Checked against 4 published copies

ISO fits are metric; the inch columns convert them. ANSI B4.2 inch tables round differently, by a tenth or so.