SAE J429 · UNF

1/2-20 UNF bolt torque

1/2-20 UNF Grade 5: 85.0 ft·lb dry, 63.7 ft·lb lubricated, for a steel bolt tightened to 75% of its proof load.

A 1/2-20 UNF Grade 5 bolt clamping two plates, in section: the head and the nut squeeze the joint with the clamp load.clamp load 10,197 lbfbolt 1/2-20 UNF Grade 5jointnut
1/2-20 UNF Grade 5 at 75% of its proof load. Not to scale.

Tightening torque

1/2-20 UNF tightening torque by grade, dry and lubricated
GradeDry ft·lbLubed ft·lbDry N·mLubed N·mClamp load
Grade 255.041.274.555.96,598 lbf
Grade 585.063.711586.410,197 lbf
Grade 812090.016312214,396 lbf

From the standard, ASME B1.1 tensile stress area

1 ft·lb = 1.355818 N·m. Lubricated is about 75% of dry (K 0.15 vs 0.20) for the same clamp load.

What these values assume

The preload, the nut factor and the formula
  • Clamp load is 75% of the proof load of the bolt's grade (SAE J429, ISO 898-1), the usual preload for a reusable joint.
  • Dry: K = 0.20, plain steel threads as received. Lubricated: K = 0.15, oiled threads. Plated, waxed or thread-locked threads take a different K and less torque.
  • Torque T = K × D × F, D the nominal diameter, F the clamp load; tensile stress area from ASME B1.1 or ISO 898-1.
  • Steel bolt and nut (or tapped hole) at least as strong as the bolt. Tapped aluminum or cast iron needs less.

Two published copies agree

A starting value, not a spec. Torque is only an indirect measure of clamp load: thread and under-head friction decide how much of it becomes clamp. The joint designer's or equipment maker's torque wins.

Published charts

What published charts print for 1/2-20 UNF

Dry, on the same basis (75% of proof, K 0.20), in ft·lb.

Grade 2
Fewer than two published charts print this size; the torque above is the formula's.
Grade 5
85.0 ft·lb (charts print 84.9–85.0)Only two makers publish this: Fastenal and AIMS Industrial
Grade 8
120 ft·lb (charts print 120–120)Only two makers publish this: Fastenal and AIMS Industrial

Only two makers publish this: Fastenal and AIMS Industrial

How it's worked

The arithmetic for Grade 5

As = .7854 × (0.5000 − .9743 / 20)² = 0.1600 in². Grade 5: F = .75 × 0.1600 × 85,000 psi = 10,197 lbf; dry T = .20 × 0.5000 × 10,197 / 12 = 85.0 ft·lb.

Sources

Sources8