Assembly

Bolt torque calculator

Tightening torque for the clamp load you want, by thread, grade and lubrication.

Tightening torque

106ft·lb

Torque
106 ft·lb · 1,277 in·lb · 144 N·m
Clamp
12,771 lbf (75% of proof)
Proof load
17,028 lbf
Stress area
.1419 in²
K
0.2

Published charts print 106–107 ft·lb

Median of 3 makers

Why: 75% of the Grade 8 proof load is 12,771 lbf of clamp; with K 0.2 that takes 106 ft·lb.

Find
Inch 1/4″–1-1/2″, metric M5–M39
Grade
Threads
Preload

Every size at a glance: bolt torque chart.

Why these numbers?
  1. The situation

    Grade 8 is proven to 120,000 psi without taking a set: over the .1419 in² stress area of 1/2-13 UNC, a proof load of 17,028 lbf.

    Two sources: Portland Bolt and Fastenal , sources [1, 2]

  2. What that means

    Clamp a joint you will take apart again to 75% of proof: 12,771 lbf. High enough to hold the joint tight, with margin below the load that stretches the bolt for good.

    3 sources agree , sources [3, 4, 5]

  3. What that means

    The thread condition sets how much clamp a torque buys, the nut factor K: 0.20 for plain steel threads as received.

    4 sources agree , sources [6, 7, 8, 9]

  4. The number

    T = K × D × F = 0.2 × 0.5" × 12,771 lbf ÷ 12 = 106 ft·lb.

    Geometry: exact by definition

How we source these numbers

What next

Which tap drill for this thread?Tap drill size for any thread, cut or form tap, by percent of thread.
What limits give this fit?Hole and shaft limits for an ISO fit like H7/g6, and how tightly they mate.
Where do the holes on this bolt circle go?X and Y for every hole on a bolt circle, plus a G81 drilling program.
How the bolt torque calculator works

A 1/2-13 Grade 8 bolt clamped to 12,771 lbf takes 106 ft·lb with dry threads, or 80 ft·lb oiled for the same clamp.

Bolt torque from clamp load: the formula and how to use it

Maintained by John, former CNC lathe programmer

What it calculates

This bolt torque calculator gives the tightening torque for any inch or metric bolt from its thread, grade, thread condition and the clamp load you want, as a share of the grade’s proof load. Run it the other way and it tells you how much clamp load a torque you already have puts on the bolt, and how close that is to the proof load.

It is the interactive side of the bolt torque chart: the chart prints the usual 75% of proof, dry and oiled, for the common sizes; here you can pick 90% for a permanent joint, your own nut factor K for a plated or waxed fastener, or a fine or special pitch the chart leaves out.

The formulas

Clamp load (preload)

F = share × As × Sp

share
0.75 for a joint you will take apart again, 0.90 for a permanent one
As
tensile stress area of the thread, in² or mm²
Sp
proof stress of the grade, psi or MPa (SAE J429, ISO 898-1)

Tightening torque

T = K × D × F (÷ 12 for ft·lb, ÷ 1000 for N·m)

K
nut factor: 0.20 dry steel as received, 0.15 oiled
D
nominal diameter, inches or mm
F
clamp load, lbf or N

Stress area

As = 0.7854 × (D − 0.9743 ÷ n)²

As = 0.7854 × (d − 0.9382 × P)²

n
threads per inch (ASME B1.1)
P
pitch in mm (ISO 898-1)

Clamp load from a torque (the reverse)

F = T ÷ (K × D)

T
torque in in·lb with D in inches, or N·mm with d in mm

Worked example

A 1/2-13 Grade 8 bolt, plain dry threads, a joint that will be taken apart again (75% of proof).

  1. As = 0.7854 × (0.5 − 0.9743 ÷ 13)² = 0.7854 × 0.4251² = 0.1419 in².
  2. Proof load = 0.1419 × 120,000 psi = 17,028 lbf; clamp at 75% = 12,771 lbf.
  3. T = 0.20 × 0.5 × 12,771 = 1,277 in·lb ÷ 12 = 106 ft·lb. Fastenal’s chart prints 106.
  4. Oiled (K 0.15): 0.15 × 0.5 × 12,771 ÷ 12 = 80 ft·lb for the same clamp.
  5. Reverse: 80 ft·lb on dry threads clamps 80 × 12 ÷ (0.20 × 0.5) = 9,600 lbf, only 56% of proof.

Torque it to 106 ft·lb dry, or 80 ft·lb if the threads are oiled. Both give the same 12,771 lbf of clamp.

How to use it

What you enter

Thread
As written on the print: 1/2-13, 3/8-24, M10, M12x1.25. Inch 1/4″ to 1-1/2″ (SAE J429’s range), metric M5 to M39.
Grade
SAE Grade 2, 5 or 8 by the head marks (none, three lines, six lines); ISO class 8.8, 10.9 or 12.9 stamped on the head.
Threads
Dry for plain steel as received, oiled for lubricated threads, or your own K from the fastener or lubricant maker.
Preload
75% of proof for a joint you will reuse, 90% for a permanent one, or your own share.

What you get

Torque
In ft·lb, in·lb and N·m. Under 20 ft·lb the readout leads with in·lb, the way small screws are wrenched.
Clamp load
The bolt tension the torque makes, and that as a share of the proof load.
Published charts
At 75% and dry, what the charts print for that size, with how many agree.

Common mistakes

  • A dry torque on oiled threads. Oil lowers K from 0.20 to 0.15, so the dry torque clamps 1.33× harder. At 75% of proof that is 100%: the bolt is at the edge of stretching for good.
  • Mixing ft·lb and in·lb. A 1/4-20 Grade 5 wants about 8.5 ft·lb dry, which is 101 in·lb. Set an in·lb wrench to 8.5 and the bolt is barely snug.
  • Torquing into soft material. These values assume a steel nut or tapped hole at least as strong as the bolt. A tapped hole in aluminum or cast iron strips first.
  • Re-using stretched bolts. A bolt taken to the permanent 90% is near its proof load. Replace it rather than torque it again.

Sources

Proof stresses are checked against copies of SAE J429 and ISO 898-1. The 75% share is the same in all three references and 90% in two (Engineers Edge prints 0.89). K is the median of the charts that print it. The torque itself is the formula: a starting value, and the joint designer’s or equipment maker’s torque wins.

How we pick and check sources