Assembly
Bolt torque calculator
Tightening torque for the clamp load you want, by thread, grade and lubrication.
Tightening torque
106ft·lb
- Torque
- 106 ft·lb · 1,277 in·lb · 144 N·m
- Clamp
- 12,771 lbf (75% of proof)
- Proof load
- 17,028 lbf
- Stress area
- .1419 in²
- K
- 0.2
Published charts print 106–107 ft·lb
Median of 3 makers
Why: 75% of the Grade 8 proof load is 12,771 lbf of clamp; with K 0.2 that takes 106 ft·lb.
Every size at a glance: bolt torque chart.
Why these numbers?
The situation
Grade 8 is proven to 120,000 psi without taking a set: over the .1419 in² stress area of 1/2-13 UNC, a proof load of 17,028 lbf.
Two sources: Portland Bolt and Fastenal , sources [1, 2]
What that means
Clamp a joint you will take apart again to 75% of proof: 12,771 lbf. High enough to hold the joint tight, with margin below the load that stretches the bolt for good.
3 sources agree , sources [3, 4, 5]
What that means
The thread condition sets how much clamp a torque buys, the nut factor K: 0.20 for plain steel threads as received.
4 sources agree , sources [6, 7, 8, 9]
The number
T = K × D × F = 0.2 × 0.5" × 12,771 lbf ÷ 12 = 106 ft·lb.
Geometry: exact by definition
Sources
- Portland Bolt — Strength requirements by grade (SAE J429)
- Fastenal — Mechanical properties of inch fasteners (SAE J429)
- Machinery’s Handbook, 31st ed. — Bolt preload: Fi = 0.75 × At × Sp for reusable connections, 0.9 × At × Sp for permanent
- MIT OpenCourseWare — 2.72 Elements of mechanical design, lecture 10 (bolted joints): non-permanent 0.75 Fp, permanent 0.90 Fp
- Engineers Edge — Bolt preload calculation: c = 0.75 for reuse, 0.89 for permanent connections
- Fastenal — Torque-tension relationship for A307A, Grade 5, 8 and 9 bolts (Rev 3-6-09)
- Portland Bolt — Bolt torque chart (75% of proof load)
- AIMS Industrial — Imperial bolt torque chart (SAE J429)
- Engineers Edge — Torque vs tension for SAE J429 bolts
What next
How the bolt torque calculator works
A 1/2-13 Grade 8 bolt clamped to 12,771 lbf takes 106 ft·lb with dry threads, or 80 ft·lb oiled for the same clamp.
Bolt torque from clamp load: the formula and how to use it
Maintained by John, former CNC lathe programmer
What it calculates
This bolt torque calculator gives the tightening torque for any inch or metric bolt from its thread, grade, thread condition and the clamp load you want, as a share of the grade’s proof load. Run it the other way and it tells you how much clamp load a torque you already have puts on the bolt, and how close that is to the proof load.
It is the interactive side of the bolt torque chart: the chart prints the usual 75% of proof, dry and oiled, for the common sizes; here you can pick 90% for a permanent joint, your own nut factor K for a plated or waxed fastener, or a fine or special pitch the chart leaves out.
The formulas
Clamp load (preload)
F = share × As × Sp
- share
- 0.75 for a joint you will take apart again, 0.90 for a permanent one
- As
- tensile stress area of the thread, in² or mm²
- Sp
- proof stress of the grade, psi or MPa (SAE J429, ISO 898-1)
Tightening torque
T = K × D × F (÷ 12 for ft·lb, ÷ 1000 for N·m)
- K
- nut factor: 0.20 dry steel as received, 0.15 oiled
- D
- nominal diameter, inches or mm
- F
- clamp load, lbf or N
Stress area
As = 0.7854 × (D − 0.9743 ÷ n)²
As = 0.7854 × (d − 0.9382 × P)²
- n
- threads per inch (ASME B1.1)
- P
- pitch in mm (ISO 898-1)
Clamp load from a torque (the reverse)
F = T ÷ (K × D)
- T
- torque in in·lb with D in inches, or N·mm with d in mm
Worked example
A 1/2-13 Grade 8 bolt, plain dry threads, a joint that will be taken apart again (75% of proof).
- As = 0.7854 × (0.5 − 0.9743 ÷ 13)² = 0.7854 × 0.4251² = 0.1419 in².
- Proof load = 0.1419 × 120,000 psi = 17,028 lbf; clamp at 75% = 12,771 lbf.
- T = 0.20 × 0.5 × 12,771 = 1,277 in·lb ÷ 12 = 106 ft·lb. Fastenal’s chart prints 106.
- Oiled (K 0.15): 0.15 × 0.5 × 12,771 ÷ 12 = 80 ft·lb for the same clamp.
- Reverse: 80 ft·lb on dry threads clamps 80 × 12 ÷ (0.20 × 0.5) = 9,600 lbf, only 56% of proof.
Torque it to 106 ft·lb dry, or 80 ft·lb if the threads are oiled. Both give the same 12,771 lbf of clamp.
How to use it
What you enter
- Thread
- As written on the print: 1/2-13, 3/8-24, M10, M12x1.25. Inch 1/4″ to 1-1/2″ (SAE J429’s range), metric M5 to M39.
- Grade
- SAE Grade 2, 5 or 8 by the head marks (none, three lines, six lines); ISO class 8.8, 10.9 or 12.9 stamped on the head.
- Threads
- Dry for plain steel as received, oiled for lubricated threads, or your own K from the fastener or lubricant maker.
- Preload
- 75% of proof for a joint you will reuse, 90% for a permanent one, or your own share.
What you get
- Torque
- In ft·lb, in·lb and N·m. Under 20 ft·lb the readout leads with in·lb, the way small screws are wrenched.
- Clamp load
- The bolt tension the torque makes, and that as a share of the proof load.
- Published charts
- At 75% and dry, what the charts print for that size, with how many agree.
Common mistakes
- A dry torque on oiled threads. Oil lowers K from 0.20 to 0.15, so the dry torque clamps 1.33× harder. At 75% of proof that is 100%: the bolt is at the edge of stretching for good.
- Mixing ft·lb and in·lb. A 1/4-20 Grade 5 wants about 8.5 ft·lb dry, which is 101 in·lb. Set an in·lb wrench to 8.5 and the bolt is barely snug.
- Torquing into soft material. These values assume a steel nut or tapped hole at least as strong as the bolt. A tapped hole in aluminum or cast iron strips first.
- Re-using stretched bolts. A bolt taken to the permanent 90% is near its proof load. Replace it rather than torque it again.
Sources
Proof stresses are checked against copies of SAE J429 and ISO 898-1. The 75% share is the same in all three references and 90% in two (Engineers Edge prints 0.89). K is the median of the charts that print it. The torque itself is the formula: a starting value, and the joint designer’s or equipment maker’s torque wins.
- Machinery’s Handbook, 31st ed. — Bolt preload: Fi = 0.75 × At × Sp for reusable connections, 0.9 × At × Sp for permanent
- MIT OpenCourseWare — 2.72 Elements of mechanical design, lecture 10 (bolted joints): non-permanent 0.75 Fp, permanent 0.90 Fp
- Engineers Edge — Bolt preload calculation: c = 0.75 for reuse, 0.89 for permanent connections
- Portland Bolt — Strength requirements by grade (SAE J429)
- Fastenal — Mechanical properties of inch fasteners (SAE J429)
- TR Fastenings — Steel screws and bolts, mechanical properties (ISO 898-1)
- Engineering ToolBox — Metric bolts: minimum ultimate tensile and proof loads
- Fastenal — Torque-tension relationship, ISO 898-1 classes 4.6, 8.8, 10.9 and 12.9, coarse thread (Jan 2016)
- Fastenal — Torque-tension relationship for A307A, Grade 5, 8 and 9 bolts (Rev 3-6-09)
- Fastenal — Torque-tension relationship, ISO 898-1 classes 4.6, 8.8, 10.9 and 12.9, coarse thread (Jan 2016)
- Portland Bolt — Bolt torque chart (75% of proof load)
- AIMS Industrial — Imperial bolt torque chart (SAE J429)
- AIMS Industrial — Metric bolt torque chart (ISO 898-1)
- Engineers Edge — Torque vs tension for SAE J429 bolts