Pipe flanges · Tightening

28 bolt flange tightening pattern

Number the bolts 1 to 28 clockwise from any one. Tighten them in this cross (star) order, every pass:

1 – 15 – 8 – 22 – 4 – 18 – 11 – 25 – 6 – 20 – 13 – 27 – 2 – 16 – 9 – 23 – 5 – 19 – 12 – 26 – 3 – 17 – 10 – 24 – 7 – 21 – 14 – 28

Tightening order for 28 bolts: 1, 15, 8, 22, 4, 18, 11, 25, 6, 20, 13, 27, 2, 16, 9, 23, 5, 19, 12, 26, 3, 17, 10, 24, 7, 21, 14, 2812345678910111213141516171819202122232425262728

The pattern, in groups of four

  1. Group 1: 1, 15, 8, 22
  2. Group 2: 4, 18, 11, 25
  3. Group 3: 6, 20, 13, 27
  4. Group 4: 2, 16, 9, 23
  5. Group 5: 5, 19, 12, 26
  6. Group 6: 3, 17, 10, 24
  7. Group 7: 7, 21, 14, 28
Why this order

Each group of four is two pairs straight across, a quarter turn apart, so the gasket is pressed evenly. Each next group starts as far as it can from the groups already done. The amber line traces the first group. A crossing pattern, as Garlock's installation guide describes; we generate the exact order from one rule: fours 90° apart, each next four as far as possible from those done.

Passes

  1. Snug Run every nut down by hand, then snug each with a short wrench, in the star.
  2. 30% Every bolt to about 30% of the target torque, in the star.
  3. 60–70% Every bolt to 60–70% of the target, in the star.
  4. 100% Every bolt to the full target, in the star.
  5. Check At 100%, go bolt to bolt round the flange (1, 2, 3 …) until no nut turns any more.

The passes as the gasket makers print them, in our own words. Teadit, for one, prints 30%, 60% and 100% for its 913M spiral wound gaskets, then rounds until no nut turns.

A starting point from published gasket-maker tables. Your site’s bolting procedure, or a PCC-1 qualified joint procedure, governs pressure piping.

No ASME B16.5 flange (NPS 1/2 to 24) has 28 studs; the larger B16.47 flanges do. The pattern is the same rule.

Sources

Sources2