Pipe flanges · Tightening

4 bolt flange tightening pattern

Number the bolts 1 to 4 clockwise from any one. Tighten them in this cross (star) order, every pass:

1 – 3 – 2 – 4

Tightening order for 4 bolts: 1, 3, 2, 41234

The pattern, in groups of four

  1. Group 1: 1, 3, 2, 4
Why this order

Each group of four is two pairs straight across, a quarter turn apart, so the gasket is pressed evenly. Each next group starts as far as it can from the groups already done. The amber line traces the first group. A crossing pattern, as Garlock's installation guide describes; we generate the exact order from one rule: fours 90° apart, each next four as far as possible from those done.

Passes

  1. Snug Run every nut down by hand, then snug each with a short wrench, in the star.
  2. 30% Every bolt to about 30% of the target torque, in the star.
  3. 60–70% Every bolt to 60–70% of the target, in the star.
  4. 100% Every bolt to the full target, in the star.
  5. Check At 100%, go bolt to bolt round the flange (1, 2, 3 …) until no nut turns any more.

The passes as the gasket makers print them, in our own words. Teadit, for one, prints 30%, 60% and 100% for its 913M spiral wound gaskets, then rounds until no nut turns.

A starting point from published gasket-maker tables. Your site’s bolting procedure, or a PCC-1 qualified joint procedure, governs pressure piping.

Sources

Sources2