ASTM A193 · A320 · Pipe flange studs

Stud bolt grades: B7, B16, L7, B7M, B8 and B8M

The studs that bolt pipe flanges. ASTM A193 covers bolting for high-temperature or high-pressure service (B7, B16, B7M, B8, B8M), and A320 covers low-temperature service (L7). Here are the minimum strengths by diameter, the nut each grade takes, and why the B7 torque tables don't fit a stainless stud.

Minimum strength by diameter

Minimum yield and tensile strength of A193 and A320 stud grades by diameter, ksi
GradeDiameterYield, ksiTensile, ksiYield, MPa
A193 B7To 2-1/2"105125724
Over 2-1/2" to 4"95115655
Over 4" to 7"75100517
A193 B16To 2-1/2"105125724
Over 2-1/2" to 4"95110655
Over 4" to 7"85100586
A320 L7To 2-1/2"105125724
A193 B7MTo 4"80100552
Over 4" to 7"75100517
A193 B8 Class 1All sizes3075207
A193 B8M Class 1All sizes3075207
A193 B8M Class 2To 3/4"95110655
Over 3/4" to 1"80100552
Over 1" to 1-1/4"6595448
Over 1-1/4" to 1-1/2"5090345
  • B7:

    Checked against 3 published copies

  • B16:

    Two published copies agree

  • L7:

    Two published copies agree

  • B7M:

    Two published copies agree

  • B8 Class 1:

    Checked against 3 published copies

  • B8M Class 1:

    Checked against 3 published copies

  • B8M Class 2:

    Two published copies agree

B16 and L7 match B7's yield at every size an ASME B16.5 flange uses (to 2-1/2" for L7, the largest A320 lists). B7M is the same alloy made softer on purpose: its yield is 80 ksi to 4". Class 2 stainless is strain hardened, so its strength falls with size, and A193 lists it only to 1-1/2". MPa are converted from ksi (× 6.895), not read from the metric tables.

The nut each grade takes (ASTM A194)

  • B7 stud: A194 grade 2H nut

    Two published copies agree

  • B16 stud: not shown. Only one published copy pairs a nut with this grade.

  • L7 stud: A194 grade 4 or 7 nut

    Two published copies agree

  • B7M stud: not shown. Only one published copy pairs a nut with this grade.

  • B8 Class 1 stud: A194 grade 8 nut

    Two published copies agree

  • B8M Class 1 stud: A194 grade 8M nut

    Published copies disagree: Portland Bolt 8M; Lamons 8

  • B8M Class 2 stud: not shown. Only one published copy pairs a nut with this grade.

Flange studs take heavy hex nuts (ASME B18.2.2), 1-1/2 times the stud diameter plus 1/8" across the flats: a 3/4" stud's nut takes a 1-1/4" wrench.

Two published copies agree

Why B7 torque tables don't fit B8M Class 1

Show

Gasket makers' flange torque tables are written for B7 studs. Garlock's table and the 60 ksi table Lamons prints load each stud to about 60,000 psi. That is 57% of B7's 105,000 psi yield, but 2× the 30,000 psi yield of a B8 or B8M Class 1 stud. A table torque would stretch a Class 1 stainless stud past yield, so it would no longer hold its load.

For B8 or B8M Class 1, the calculator works the torque from a share of the stud's own yield (T = K × D × F) and labels it computed. Class 2 and B7M take the table scaled by their yield over B7's.

B8M Class 1 on a 4" Class 150 flange, in the calculator

From the standard, ASTM A193 minimum yield (copies above); T = K × D × F

Lubricant and nut factor (K)

K is the share of torque that becomes clamp: T = K × D × F. Less friction means a lower K, so the same torque gives more clamp.

Nut factor K by thread condition, and the K each gasket maker's flange torque table assumes
Condition or tableK
Plain steel, dry, as received0.2
Oiled threads0.15
Garlock's flange table (spiral wound)Not printed
Flexitallic's flange table (spiral wound)0.15–0.19
Teadit's flange table (spiral wound)0.17
FNW's flange table (spiral wound)Not printed
Gore's flange table (sheet)0.15
Thomson's flange table (sheet)0.2

Dry:

Median of 4 makers

Oiled:

Median of 3 makers

Each maker's row is what that maker prints about its own table.

Copper or nickel anti-seize, moly paste and PTFE-coated studs are not listed yet: no K for them has three agreeing published sources. Use the K your lubricant's maker prints in the calculator's "My K".

Temperature ranges

Not shown: only one published table we found (Lamons) gives a service temperature range per grade, and our rule needs two. A193's scope is high-temperature or high-pressure service, and A320's is low-temperature service. Check your piping spec for the limits.

Sources15