ISO 286 · Hole · 10–18 mm

H11 hole tolerance, 10–18 mm

H11 tolerance for holes over 10 up to 18 mm is +0.110 / 0 mm (+0.00433 / 0 in). A 12 mm H11 hole measures 12.000–12.110 mm; a 14 mm one, 14.000–14.110 mm. The table gives each common size in the range in mm and inches.

H11 hole tolerance zone, 10–18 mm: ES +110 µm, EI 0 µm against the zero line.ES +110 µmEI 0 µmtolerance zone H11zero line 10–18 mm
The tolerance zone against the zero line (the basic size). ES and EI are the hole’s upper and lower deviations. Deviations to scale; the part itself is not drawn.

H11 limits, over 10 up to 18 mm

Deviations from the nominal size. Inches are the µm values ÷ 25,400.

H11 deviations over 10 up to 18 mm
Size, mmUpper µmLower µmUpper mmLower mmUpper inLower inBand µm
10–18+1100+0.1100+0.004330110

Checked against 3 published copies

Common sizes, H11 hole

The smallest and largest hole each size allows. 10 mm itself belongs to the range below.

H11 smallest and largest size for common sizes over 10 up to 18 mm
SizeMin mmMax mmSize inMin inMax in
12 H1112.00012.1100.47240.472440.47677
14 H1114.00014.1100.55120.551180.55551
16 H1116.00016.1100.62990.629920.63425
18 H1118.00018.1100.70870.708660.71299

Checked against 3 published copies

ISO fits are metric; the inch columns convert them. ANSI B4.2 inch tables round differently, by a tenth or so.