ISO 286 · Hole · 6–10 mm
H11 hole tolerance, 6–10 mm
H11 tolerance for holes over 6 up to 10 mm is +0.090 / 0 mm (+0.00354 / 0 in). A 10 mm H11 hole measures 10.000–10.090 mm; an 8 mm one, 8.000–8.090 mm. The table gives each common size in the range in mm and inches.
H11 limits, over 6 up to 10 mm
Deviations from the nominal size. Inches are the µm values ÷ 25,400.
| Size, mm | Upper µm | Lower µm | Upper mm | Lower mm | Upper in | Lower in | Band µm |
|---|---|---|---|---|---|---|---|
| 6–10 | +90 | 0 | +0.090 | 0 | +0.00354 | 0 | 90 |
Checked against 3 published copies
Common sizes, H11 hole
The smallest and largest hole each size allows. 6 mm itself belongs to the range below.
| Size | Min mm | Max mm | Size in | Min in | Max in |
|---|---|---|---|---|---|
| 8 H11 | 8.000 | 8.090 | 0.3150 | 0.31496 | 0.31850 |
| 10 H11 | 10.000 | 10.090 | 0.3937 | 0.39370 | 0.39724 |
Checked against 3 published copies
ISO fits are metric; the inch columns convert them. ANSI B4.2 inch tables round differently, by a tenth or so.
Sources
Sources3
ISO 286-1 and 286-2. Every limit on this page comes from the same engine as the H11 chart, checked against these published copies of the tables: