ISO 898-1 · coarse
M8 × 1.25 bolt torque
M8 × 1.25 Class 10.9: 36.5 N·m dry, 27.3 N·m lubricated, for a steel bolt tightened to 75% of its proof load.
Tightening torque
| Grade | Dry N·m | Lubed N·m | Dry ft·lb | Lubed ft·lb | Clamp load |
|---|---|---|---|---|---|
| Class 8.8 | 25.5 | 19.1 | 18.8 | 14.1 | 15.9 kN |
| Class 10.9 | 36.5 | 27.3 | 26.9 | 20.2 | 22.8 kN |
| Class 12.9 | 42.6 | 32.0 | 31.4 | 23.6 | 26.6 kN |
From the standard, ISO 898-1 tensile stress area
1 ft·lb = 1.355818 N·m. Lubricated is about 75% of dry (K 0.15 vs 0.20) for the same clamp load.
What these values assume
The preload, the nut factor and the formula
- Clamp load is 75% of the proof load of the bolt's grade (SAE J429, ISO 898-1), the usual preload for a reusable joint.
- Dry: K = 0.20, plain steel threads as received. Lubricated: K = 0.15, oiled threads. Plated, waxed or thread-locked threads take a different K and less torque.
- Torque T = K × D × F, D the nominal diameter, F the clamp load; tensile stress area from ASME B1.1 or ISO 898-1.
- Steel bolt and nut (or tapped hole) at least as strong as the bolt. Tapped aluminum or cast iron needs less.
Two published copies agree
A starting value, not a spec. Torque is only an indirect measure of clamp load: thread and under-head friction decide how much of it becomes clamp. The joint designer's or equipment maker's torque wins.
Published charts
What published charts print for M8 × 1.25
Dry, on the same basis (75% of proof, K 0.20), in N·m.
- Class 8.8
- 25.8 N·m (charts print 25.5–26.0)Only two makers publish this: Fastenal and AIMS Industrial
- Class 10.9
- 36.8 N·m (charts print 36.5–37.0)Only two makers publish this: Fastenal and AIMS Industrial
- Class 12.9
- 42.8 N·m (charts print 42.6–43.0)Only two makers publish this: Fastenal and AIMS Industrial
Only two makers publish this: Fastenal and AIMS Industrial
How it's worked
The arithmetic for Class 10.9
As = .7854 × (8 − .9382 × 1.25)² = 36.6 mm². Class 10.9: F = .75 × 36.6 × 830 MPa = 22,789 N; dry T = .20 × 8 mm × 22,789 N = 36.5 N·m.
Sources
Sources9
- TR Fastenings — Steel screws and bolts, mechanical properties (ISO 898-1) (archived Oct 18, 2026)
- Engineering ToolBox — Metric bolts: minimum ultimate tensile and proof loads (archived Apr 27, 2026)
- Fastenal — Torque-tension relationship, ISO 898-1 classes 4.6, 8.8, 10.9 and 12.9, coarse thread (Jan 2016) (archived Oct 26, 2026)
- Fastenal — Torque-tension relationship for A307A, Grade 5, 8 and 9 bolts (Rev 3-6-09) (archived Jul 12, 2023)
- Fastenal — Torque-tension relationship, ISO 898-1 classes 4.6, 8.8, 10.9 and 12.9, coarse thread (Jan 2016) (archived Oct 26, 2026)
- Portland Bolt — Bolt torque chart (75% of proof load) (archived Jul 22, 2026)
- AIMS Industrial — Imperial bolt torque chart (SAE J429) (archived Nov 13, 2026)
- AIMS Industrial — Metric bolt torque chart (ISO 898-1) (archived Nov 13, 2026)
- Engineers Edge — Torque vs tension for SAE J429 bolts (archived Oct 15, 2024)