Fabrication
Bend allowance calculator
Bend allowance and bend deduction from thickness, inside radius, angle and K-factor.
Flat length
4.8599in
- Bend allowance
- .2359
- Outside setback
- .1880
- Bend deduction
- .1401
- K
- 0.4
- Thickness
- .0630
Why: Cut the blank 4.8599": the outside flanges less a .1401" bend deduction.
90 for a right angle; 0 is flat
From your shop’s bend tests or your CAD sheet metal setting
Outside dimension, as on the print
Outside dimension, as on the print
Why these numbers?
The situation
Bending stretches the outside of the bend and compresses the inside. One layer in between keeps its length: the neutral axis.
Two sources: Durma and Javelin Technologies , sources [1, 2]
What that means
K is where that layer sits, as a fraction of the thickness from the inside. It depends on the material, the thickness and the bend radius.
Two sources: Durma and Javelin Technologies , sources [1, 2]
What that means
K = 0.4, your number.
From your input: your K
So
The blank needs that layer’s arc length for the bend: BA = 90° × π/180 × (.1250" + 0.4 × .0630") = .2359".
Geometry: exact by definition
The number
Prints dimension flanges to the outside, which overlap the bend by the setback, tan(45°) × (R + T) = .1880", on each side: bend deduction = 2 × .1880" − .2359" = .1401".
Geometry: exact by definition
Sources
What next
How the bend allowance calculator works
A 90° bend in 0.063 in aluminum on a 0.125 in inside radius at K 0.40 has a bend allowance of 0.2359 in and a bend deduction of 0.1401 in, so 2 in and 3 in flanges come from a 4.860 in blank.
Bend allowance and bend deduction: the formulas and how to use them
Maintained by John, former CNC lathe programmer
What it calculates
This bend allowance calculator gives the bend allowance, outside setback and bend deduction for a sheet metal bend from the thickness, inside radius, bend angle and K-factor, and the flat blank length when you enter the two flange lengths from the print. It takes the thickness typed or from a gauge number, and the angle as the angle of bend or the included angle.
The K-factor can come from Durma’s published starting values by bending method, radius and material, from your own number, or from a test bend: bend a measured blank, enter what you measured, and it works out the K your brake, tooling and material really give.
The formulas
Bend allowance (the arc on the neutral axis)
BA = θ × π ÷ 180 × (R + K × T)
- θ
- angle of bend in degrees (90 for a right angle)
- R
- inside bend radius
- K
- K-factor: where the neutral axis sits, as a fraction of T from the inside
- T
- material thickness
Outside setback
OSSB = tan(θ ÷ 2) × (R + T)
- OSSB
- from the outside mold line, where the flanges’ outside faces meet, to the start of the bend
Bend deduction and flat length
BD = 2 × OSSB − BA
flat = A + B − BD
- A, B
- the two flange lengths measured to the outside, as most prints dimension them
K from a test bend
BA = flat − (A − OSSB) − (B − OSSB)
K = (BA ÷ (θ × π ÷ 180) − R) ÷ T
- flat
- the measured length of the test blank before bending
Worked example
A 90° bend in .063″ aluminum with a .125″ inside radius and K = 0.40, flanges 2″ and 3″ to the outside.
- BA = 90 × π ÷ 180 × (.125 + 0.40 × .063) = 1.5708 × .1502 = .2359″.
- OSSB = tan 45° × (.125 + .063) = 1 × .188 = .1880″.
- BD = 2 × .1880 − .2359 = .1401″.
- Flat = 2 + 3 − .1401 = 4.8599″. Check: (2 − .188) + .2359 + (3 − .188) = 4.8599″.
Cut the blank 4.860″ long and the bent part measures 2″ by 3″ to the outside.
How to use it
What you enter
- Thickness
- Typed, or a gauge number in the steel, galvanized, stainless or aluminum gauge system; each system gives a different thickness for the same number.
- Inside radius
- The radius on the inside of the bend. In an air bend it is set mostly by the die opening, not the punch.
- Angle
- Angle of bend (how far the flange moves, 90 for a right angle) or the included angle between the flanges; one is 180 minus the other.
- K-factor
- From Durma’s table, your own number, or a test bend.
- Flanges
- Optional. Outside dimensions from the print, for the flat length.
What you get
- Flat length
- The blank length for the two flanges, when both are entered.
- Bend allowance
- The length of material that goes into the bend, on the neutral axis.
- Outside setback and bend deduction
- How far the bend sits in from the outside corner, and what comes off the flange sum.
Common mistakes
- Entering the included angle as the bend angle. A 135° included angle is a 45° bend. Entered as 135° of bend, the allowance is three times too long.
- Adding the bend allowance to outside dimensions. Outside flange lengths already include the setback twice. Subtract the bend deduction, or add the allowance to the flat (tangent-to-tangent) legs only.
- Mixing gauge systems. 16 gauge is .0598″ in steel, .0625″ in stainless and .0508″ in aluminum. Pick the gauge system for the material.
- Trusting a table K for tight work. K moves with the material, the radius, the die and the bending method. For parts with tight tolerances, bend a test piece and use the K it gives.
Sources
The formulas are geometry, cited rather than counted; Durma, Javelin and Firgelli state them the same way. The K-factor starting values are Durma’s, a press brake maker and the one maker found that publishes them, so they carry its name and are a starting point, not a measurement.
- Durma — Sheet metal bending: bend allowance calculation guide (BA formula, generic K-factors)
- Javelin Technologies — What are bend allowance, bend deduction and K-factor? (SOLIDWORKS sheet metal)
- Firgelli Automations — Bend allowance calculator (BA, outside setback, bend deduction, worked 90° example)