Inspection · ISO 2768

ISO 2768-c tolerances (coarse)

ISO 2768-c (coarse) allows ±0.2 mm from 0.5 up to 3 mm, ±0.3 mm over 3 up to 6, ±0.5 mm over 6 up to 30, ±0.8 mm over 30 up to 120 and ±1.2 mm over 120 up to 400. Angles get ±1°30′ when the shorter side is up to 10 mm, down to ±0°10′ over 400 mm. The table below runs to 4000 mm, in mm and inches.

Look up a size in ISO 2768-c →

The ISO 2768-c (coarse) linear tolerance by size range, as a band: ± about the nominal size, each range’s value labelled.±0.2±0.3±0.5±0.8±1.2±2±3±40.53630120400100020004000mm
ISO 2768-c: ± mm by size. Heights to scale with each other; the size ranges are not.

Linear sizes, class c

ISO 2768-c linear tolerances by size range
Size, mm± mm± inch
0.5 up to 3±0.2±.0079"
over 3 up to 6±0.3±.0118"
over 6 up to 30±0.5±.0197"
over 30 up to 120±0.8±.0315"
over 120 up to 400±1.2±.0472"
over 400 up to 1000±2±.0787"
over 1000 up to 2000±3±.1181"
over 2000 up to 4000±4±.1575"

Size ranges are in millimetres, as the standard sets them; a size on a boundary takes the lower row. A dash means no value: tolerance it on the drawing.

Two published copies agree

Broken edges and angles

Broken edges (external radii and chamfer heights)

ISO 2768-c broken edge tolerances
Size, mm± mm± inch
0.5 up to 3±0.4±.0157"
over 3 up to 6±1±.0394"
over 6±2±.0787"

Angles, by the shorter side

ISO 2768-c angular tolerances
Shorter side, mm±
up to 10±1°30′
over 10 up to 50±1°
over 50 up to 120±0°30′
over 120 up to 400±0°15′
over 400±0°10′

On the shop floor

How the print applies it

A general tolerance applies only to dimensions printed without one. If the print says ISO 2768-c, every untoleranced size on it gets these limits, and the size ranges are metric even on an inch-dimensioned job: convert the size, find its row, then convert the tolerance back. The standard also says a part outside a general tolerance isn’t rejected automatically if it still works, so ask before you scrap one.