Inspection · ISO 2768
ISO 2768-K geometric tolerances
ISO 2768-K allows 0.05 mm of straightness or flatness up to 10 mm, 0.2 mm over 30 up to 100 and 0.4 mm over 100 up to 300; 0.4 mm of perpendicularity on a shorter side up to 100 mm; 0.6 mm of symmetry up to 100 mm; and 0.2 mm of circular runout. ISO 2768-2 was withdrawn in 2021 (now ISO 22081) but is still on many drawings.
Look up a size in ISO 2768-K →
Geometric tolerances, class K
From ISO 2768-2, withdrawn in 2021 and replaced by ISO 22081. Prints that call “ISO 2768-…K” still use these values.
Straightness and flatness
| Length, mm | mm | inch |
|---|---|---|
| up to 10 | 0.05 | .0020" |
| over 10 up to 30 | 0.1 | .0039" |
| over 30 up to 100 | 0.2 | .0079" |
| over 100 up to 300 | 0.4 | .0157" |
| over 300 up to 1000 | 0.6 | .0236" |
| over 1000 up to 3000 | 0.8 | .0315" |
Two published copies agree
Perpendicularity, symmetry and runout
Perpendicularity, by the shorter side
| Shorter side, mm | mm | inch |
|---|---|---|
| up to 100 | 0.4 | .0157" |
| over 100 up to 300 | 0.6 | .0236" |
| over 300 up to 1000 | 0.8 | .0315" |
| over 1000 up to 3000 | 1 | .0394" |
Symmetry
| Length, mm | mm | inch |
|---|---|---|
| up to 100 | 0.6 | .0236" |
| over 100 up to 300 | 0.6 | .0236" |
| over 300 up to 1000 | 0.8 | .0315" |
| over 1000 up to 3000 | 1 | .0394" |
Circular runout: 0.2 mm (.0079"), radial or axial, at any size.
On the shop floor
How the print applies it
Class K covers form and position on features with no geometric tolerance of their own: how flat a face, how square a step, how central a slot, how much a diameter runs out. Circularity is limited to the size tolerance (but never more than the runout value), and parallelism to the size or flatness tolerance, whichever is bigger. Cylindricity, profile, angularity, coaxiality, position and total runout get no general tolerance.