Inspection · ISO 2768
ISO 2768-m tolerances (medium)
ISO 2768-m (medium) allows ±0.1 mm from 0.5 up to 6 mm, ±0.2 mm over 6 up to 30, ±0.3 mm over 30 up to 120 and ±0.5 mm over 120 up to 400. Angles get ±1° when the shorter side is up to 10 mm, down to ±0°5′ over 400 mm. The table below runs to 4000 mm, in mm and inches.
Look up a size in ISO 2768-m →
Linear sizes, class m
| Size, mm | ± mm | ± inch |
|---|---|---|
| 0.5 up to 3 | ±0.1 | ±.0039" |
| over 3 up to 6 | ±0.1 | ±.0039" |
| over 6 up to 30 | ±0.2 | ±.0079" |
| over 30 up to 120 | ±0.3 | ±.0118" |
| over 120 up to 400 | ±0.5 | ±.0197" |
| over 400 up to 1000 | ±0.8 | ±.0315" |
| over 1000 up to 2000 | ±1.2 | ±.0472" |
| over 2000 up to 4000 | ±2 | ±.0787" |
Size ranges are in millimetres, as the standard sets them; a size on a boundary takes the lower row. A dash means no value: tolerance it on the drawing.
Two published copies agree
Broken edges and angles
Broken edges (external radii and chamfer heights)
| Size, mm | ± mm | ± inch |
|---|---|---|
| 0.5 up to 3 | ±0.2 | ±.0079" |
| over 3 up to 6 | ±0.5 | ±.0197" |
| over 6 | ±1 | ±.0394" |
Angles, by the shorter side
| Shorter side, mm | ± |
|---|---|
| up to 10 | ±1° |
| over 10 up to 50 | ±0°30′ |
| over 50 up to 120 | ±0°20′ |
| over 120 up to 400 | ±0°10′ |
| over 400 | ±0°5′ |
On the shop floor
How the print applies it
A general tolerance applies only to dimensions printed without one. If the print says ISO 2768-m, every untoleranced size on it gets these limits, and the size ranges are metric even on an inch-dimensioned job: convert the size, find its row, then convert the tolerance back. The standard also says a part outside a general tolerance isn’t rejected automatically if it still works, so ask before you scrap one.