ISO 286 · Shaft

p6 shaft tolerance

p6 tolerance on a 25 mm shaft is +0.035 / +0.022 mm, so the shaft measures 25.022–25.035 mm. A p shaft sits above the nominal size, for transition and interference fits in an H hole. Grade 6 (IT6) sets the band’s width; the chart below gives it for every size to 500 mm.

P6 hole on 25 mm: −0.018 / −0.031 mm. P6 hole tolerance

p6 shaft tolerance zone for every size range from 0–3 mm to 400–500 mm, against the zero line; 18–30 mm is +35 / +22 µm.tolerance zone p6, 18–30 mm: +35 / +22 µmsize range 0–3 to 400–500 mm
One band per size range against the zero line. The marked band holds 25 mm. Deviations to scale; the size ranges are evenly spaced, not to scale.

Limits by size

Deviations from the nominal size, over the first size up to and including the second. Inches are µm ÷ 25,400; ANSI B4.2 inch tables round differently, by a tenth or so.

p6 limits by nominal size
Size, mmUpper µmLower µmUpper inLower in
0–3+12+6+0.00047+0.00024
3–6+20+12+0.00079+0.00047
6–10+24+15+0.00094+0.00059
10–18+29+18+0.00114+0.00071
18–30+35+22+0.00138+0.00087
30–50+42+26+0.00165+0.00102
50–80+51+32+0.00201+0.00126
80–120+59+37+0.00232+0.00146
120–180+68+43+0.00268+0.00169
180–250+79+50+0.00311+0.00197
250–315+88+56+0.00346+0.00220
315–400+98+62+0.00386+0.00244
400–500+108+68+0.00425+0.00268

Checked against 4 published copies