ISO 286 · Shaft

g6 shaft tolerance

g6 tolerance on a 25 mm shaft is −0.007 / −0.020 mm, so the shaft measures 24.980–24.993 mm. A g shaft sits wholly below the nominal size, so it clears an H hole. Grade 6 (IT6) sets the band’s width; the chart below gives it for every size to 500 mm.

G6 hole on 25 mm: +0.020 / +0.007 mm. G6 hole tolerance

g6 shaft tolerance zone for every size range from 0–3 mm to 400–500 mm, against the zero line; 18–30 mm is −7 / −20 µm.tolerance zone g6, 18–30 mm: −7 / −20 µmsize range 0–3 to 400–500 mm
One band per size range against the zero line. The marked band holds 25 mm. Deviations to scale; the size ranges are evenly spaced, not to scale.

Limits by size

Deviations from the nominal size, over the first size up to and including the second. Inches are µm ÷ 25,400; ANSI B4.2 inch tables round differently, by a tenth or so.

g6 limits by nominal size
Size, mmUpper µmLower µmUpper inLower in
0–3−2−8−0.00008−0.00031
3–6−4−12−0.00016−0.00047
6–10−5−14−0.00020−0.00055
10–18−6−17−0.00024−0.00067
18–30−7−20−0.00028−0.00079
30–50−9−25−0.00035−0.00098
50–80−10−29−0.00039−0.00114
80–120−12−34−0.00047−0.00134
120–180−14−39−0.00055−0.00154
180–250−15−44−0.00059−0.00173
250–315−17−49−0.00067−0.00193
315–400−18−54−0.00071−0.00213
400–500−20−60−0.00079−0.00236

Checked against 4 published copies

Fits that use g6

Fits that use g6
  • H7/g6 · Sliding: Not to run freely, but to move and turn freely and locate accurately
Any size and fit in the calculator

Sources

Sources4