ISO 286 · Fit

H7/f6 fit

H7/f6 at 25 mm: 0.020–0.054 mm clearance, a clearance fit. The hole is 25.000–25.021 mm and the shaft 24.967–24.980 mm. The table gives it for every size to 500 mm.

H7/f6 fit at 25 mm: hole H7 +21 / 0 µm, shaft f6 −20 / −33 µm, a clearance fit.hole H7 +21 / 0 µmshaft f6 −20 / −33 µmzero line 25 mmclearance 20 to 54 µm
The hole and shaft zones at 25 mm, against the zero line (the basic size). Deviations to scale; the parts themselves are not drawn.

H7/f6 by size range

Checked against 4 published copies

Every size to 500 mm

Hole and shaft deviations in µm. Fit: plus is clearance, minus is interference, from the loosest to the tightest pair. Each range is over the first size, up to and including the second.

H7/f6 hole and shaft limits and fit by nominal size
Size, mmH7 µmf6 µmLoosest mmTightest mmLoosest inTightest in
0–3+10 / 0−6 / −12+0.022+0.006+0.00087+0.00024
3–6+12 / 0−10 / −18+0.030+0.010+0.00118+0.00039
6–10+15 / 0−13 / −22+0.037+0.013+0.00146+0.00051
10–18+18 / 0−16 / −27+0.045+0.016+0.00177+0.00063
18–30+21 / 0−20 / −33+0.054+0.020+0.00213+0.00079
30–50+25 / 0−25 / −41+0.066+0.025+0.00260+0.00098
50–80+30 / 0−30 / −49+0.079+0.030+0.00311+0.00118
80–120+35 / 0−36 / −58+0.093+0.036+0.00366+0.00142
120–180+40 / 0−43 / −68+0.108+0.043+0.00425+0.00169
180–250+46 / 0−50 / −79+0.125+0.050+0.00492+0.00197
250–315+52 / 0−56 / −88+0.140+0.056+0.00551+0.00220
315–400+57 / 0−62 / −98+0.155+0.062+0.00610+0.00244
400–500+63 / 0−68 / −108+0.171+0.068+0.00673+0.00268

Inches are the µm values ÷ 25,400. American inch fits (RC, LC, FN classes) are a different system.

What H7/f6 is for

Only one of the fit guides we read describes H7/f6, so we don’t state a use. The limits above are ISO 286’s, from the same tables as every other fit.

Sources

Sources4