ISO 286 · Fit · locational clearance

H7/h6 fit

H7/h6 at 25 mm: 0.000–0.034 mm clearance, a locational clearance fit. The hole is 25.000–25.021 mm and the shaft 24.987–25.000 mm. Fit guides agree it is for accurate location of parts that still go together by hand. The table gives it for every size to 500 mm.

H7/h6 fit at 25 mm: hole H7 +21 / 0 µm, shaft h6 0 / −13 µm, a clearance fit.hole H7 +21 / 0 µmshaft h6 0 / −13 µmzero line 25 mmclearance 0 to 34 µm
The hole and shaft zones at 25 mm, against the zero line (the basic size). Deviations to scale; the parts themselves are not drawn.

H7/h6 by size range

Checked against 4 published copies

Every size to 500 mm

Hole and shaft deviations in µm. Fit: plus is clearance, minus is interference, from the loosest to the tightest pair. Each range is over the first size, up to and including the second.

H7/h6 hole and shaft limits and fit by nominal size
Size, mmH7 µmh6 µmLoosest mmTightest mmLoosest inTightest in
0–3+10 / 00 / −6+0.0160+0.000630
3–6+12 / 00 / −8+0.0200+0.000790
6–10+15 / 00 / −9+0.0240+0.000940
10–18+18 / 00 / −11+0.0290+0.001140
18–30+21 / 00 / −13+0.0340+0.001340
30–50+25 / 00 / −16+0.0410+0.001610
50–80+30 / 00 / −19+0.0490+0.001930
80–120+35 / 00 / −22+0.0570+0.002240
120–180+40 / 00 / −25+0.0650+0.002560
180–250+46 / 00 / −29+0.0750+0.002950
250–315+52 / 00 / −32+0.0840+0.003310
315–400+57 / 00 / −36+0.0930+0.003660
400–500+63 / 00 / −40+0.1030+0.004060

Inches are the µm values ÷ 25,400. American inch fits (RC, LC, FN classes) are a different system.

What H7/h6 is for

For accurate location of parts that still go together by hand. 2 published fit guides agree on that.

The fit guides

Sources

Sources4