ISO 286 · Fit · locational interference

P7/h6 fit

P7/h6 at 25 mm: 0.001–0.035 mm interference, an interference fit. The hole is 24.965–24.986 mm and the shaft 24.987–25.000 mm. Fit guides agree it is for the shaft-basis twin of H7/p6, pressed in. The table gives it for every size to 500 mm.

P7/h6 fit at 25 mm: hole P7 −14 / −35 µm, shaft h6 0 / −13 µm, a interference fit.hole P7 −14 / −35 µmshaft h6 0 / −13 µmzero line 25 mminterference 1 to 35 µm
The hole and shaft zones at 25 mm, against the zero line (the basic size). Deviations to scale; the parts themselves are not drawn.

P7/h6 by size range

Checked against 4 published copies

Every size to 500 mm

Hole and shaft deviations in µm. Fit: plus is clearance, minus is interference, from the loosest to the tightest pair. Each range is over the first size, up to and including the second.

P7/h6 hole and shaft limits and fit by nominal size
Size, mmP7 µmh6 µmLoosest mmTightest mmLoosest inTightest in
0–3−6 / −160 / −60−0.0160−0.00063
3–6−8 / −200 / −80−0.0200−0.00079
6–10−9 / −240 / −90−0.0240−0.00094
10–18−11 / −290 / −110−0.0290−0.00114
18–30−14 / −350 / −13−0.001−0.035−0.00004−0.00138
30–50−17 / −420 / −16−0.001−0.042−0.00004−0.00165
50–80−21 / −510 / −19−0.002−0.051−0.00008−0.00201
80–120−24 / −590 / −22−0.002−0.059−0.00008−0.00232
120–180−28 / −680 / −25−0.003−0.068−0.00012−0.00268
180–250−33 / −790 / −29−0.004−0.079−0.00016−0.00311
250–315−36 / −880 / −32−0.004−0.088−0.00016−0.00346
315–400−41 / −980 / −36−0.005−0.098−0.00020−0.00386
400–500−45 / −1080 / −40−0.005−0.108−0.00020−0.00425

Inches are the µm values ÷ 25,400. American inch fits (RC, LC, FN classes) are a different system.

What P7/h6 is for

For the shaft-basis twin of H7/p6, pressed in. 3 published fit guides agree on that.

The fit guides

Sources

Sources4